- Infoshare
-
Signed in: Administrator
- Change Password
- Signoff
- Online Documentation
- Adutante ver. 5.0.1.0
PAGE TITLE
Date Last ModifiedPAGE TITLE
Date Last Modified
CLI (Command Line Interface)How to use CLI Tool - refer to CLI Tool Overview |
GUI (Graphical User Interface) |
|
|
Alarm configuration settings can be reached by navigating to Setup->Alarms->Edit |
GUI Setting | Command Format | Description | Extra Notes |
Alarm Settings: Additional Settings for "noactivity" Alarm: |
add [system | thread | noactivity | drivefull | login | request] |
add alarm |
|
remove [system | thread | noactivity | drivefull | login | request] |
remove alarm |
|
|
alarm [system | thread | noactivity | drivefull | login | request] |
alarm configuration | ||
test [system | thread | noactivity | drivefull | login | request] |
test alarm | Force test alarm | |
emails [@com,...] [y|n] |
add/remove emails to/from recipients list | ||
enable [y|n] |
enable alarms feature | If alarms feature disabled. No alarms will be issued even if added with "add" command. | |
beepperiod [sec] |
beep period (sec) default 0 (once) | Period between beeps, when alarm is issued and not reset yet. | |
sendperiod [hr] |
send email period (hr) default 0 (once) | Email can be resent periodically, until alarm is reset | |
list |
list of available alarms | ||
reset |
reset alarms | Alarms can be reset from VSLogger Monitor. Signed In drop down menu > Reset Alarms option is available to all users with Administrator permissions. |
system, thread, drivefull, login,request alarm configuration
Note: for login and request alarms email, beep, exec script and reset script entries ignored by recorder. These alarms enabled only for logging of user activity. See Log File Notes below
|
noactivity alarm configuration
|
GUI Setting | Command Format | Description | Extra Notes |
email [y|n] |
enable/disable email |
email alarm notification |
|
beep [y|n] |
enable/disable beep |
PC speaker beep generated as alarm notification |
|
log [y|n] |
enable/disable logging |
alarm notification message stored in the log file | |
exec [y|n] |
enable/disable script execution |
enable script executions , if set below | |
script [path;prm1,prmN] |
script and parameters (optional) |
script to execute on alarm | |
resetscript [path;prm1,prmN] |
reset script and parameters (optional) |
script to execute when alarm is reset by administrator | |
Extra parameters for noactivity alarm | |||
noactivitytmout [hr] |
not-recording timeout |
||
checkhours [0-23] [y|n] |
check hours for not-recording timeout |
for example: checkhours 8-17 - add range of hours checkhours 20 - add specific hour checkhours 12-14 n - remove range of hours checkhours 20 n - remove specific hour show - display current settings |
|
checkdays [1-7] [y|n] |
check days of the week for not-recording timeout (Su,Mo,Tu,We,Th,Fr,Sa) |
for example: checkdays 2-6 , add work days checkdays 4 n - remove specific day |
|
exclude [mm/dd,..] [y|n] |
exclude specific dates from check for not-recording timeout |
for example: exclude 12/31, 01/01 - exclude new year holiday exclude 01/01 n - remove specific date |
Each alarm can trigger all enabled options:
"Reset alarms" command can trigger separate reset script, if configured.
Alarm Log files
If alarms logging is enabled (log: y) two log files created in C:\ProgramData\Adutante\vslogger\log folder. One for alarms generated in Recording service, other for alarms from Connection service.